LIGO Document E1200392-v9

Initial Alignment Procedure - LBSC2 As Built

Document #:
LIGO-E1200392-v9
Document type:
E - Engineering documents
Other Versions:
LIGO-E1200392-v6
23 Apr 2013, 12:49
Abstract:
This is the procedure for the initial alignment of the Livingston BSC2. This document describes the necessary equipment and procedures for setting the initial positions and the angular alignments of the principal optics both for the cartridge installation on the test stand and the later installation of the cartridge into the chamber.
Topics:
Notes and Changes:
10/3/2014 J. Oberling: Fixed various format and cross reference issues.

20/11/2013 J. Oberling: Since this alignment is complete the As Built document is getting its own version.

Updated to reflect alignment procedure as performed on LBSC2
Added As Built document