Abstract:
A detailed analysis of the measured and calculated noise parameters associated with the displacement sensitivity of the existing BOSEM in conjunction with the as-built aLIGO Satellite Modules D0901284. A motivating reason for this analysis is the repackaging of the aLIGO Satellite Modules into a 1U rack-mounted format.
Files in Document:
  • PDF Version (SatelliteBoxNoiseAnalysis_v2.pdf, 345.5 kB)
Other Files:
Topics:
Notes and Changes:
Version 2 of this document includes analysis results useful in determining the replacement threshold of BOSEMs at end of life.
Referenced by: