LIGO Document E1201027-v1

ECR: Replacement of the coil-series resistors in the HAM-A coil drivers

Document #:
LIGO-E1201027-v1
Document type:
E - Engineering documents
Other Versions:
Abstract:
The dynamic range requirement for the aLIGO HAM-A coil driver is 35 mA p-p for frequencies 1 kHz. However, under the current design they are generating a maximum of 201 mA, which has potential for introducing unwanted actuation noise, as well as some potential for damage. An increase in the coil-series resistance by a factor of 10 will correct this problem.
Notes and Changes:
11/16/2012: Approved by Dennis Coyne & Peter Fritschel