LIGO Document T2600323-v1
- The Laser Interferometer Gravitational-Wave Observatory (LIGO) has successfully detected gravitational waves from astronomical events. Previously developed theory suggests that a similar Michelson interferometer design can be used to detect small, stochastic spacetime fluctuations induced by entropy ( geontropic fluctuations). This is the motivation for the Gravity from Quantum Entanglement of Space-Time (GQuEST) experiment. In order to perform this experiment, we need to characterize the noise of the main hardware systems. GQuEST will utilize a single-photon detector to detect signals below the quantum shot noise threshold, but it also uses a separate homodyne readout scheme which measures cross-correlated signals from two photodetectors. The experiment uses a 1550 nm laser and an analog-to-digital converter (ADC) to read voltages from modified photodetectors. The laser, the ADC, and the modified photodetectors each have some inherent noise, which we need to quantify before performing the experiment in order to distinguish real signal caused by geontropic spacetime fluctuations from background electronics and laser noise. In this report, we characterize these noise sources and establish a preliminary estimate of GQuEST's data acquisition sensitivity, based on theoretical and early experimental noise floor measurements.