This thesis covers the detector upgrade to double the input power, thereby reducing quantum shot noise, which currently limits LIGO strain sensitivity above 100Hz. First, it presents the design of the interferometer and the noises – fundamental, technical, and environmental – which contribute to the full sensitivity curve, motivating the need for high power. The details of the high power laser upgrade are discussed. Second, it presents select side effects of high power, which can result in overall losses and heighten specific classical noise couplings. The work particularly focuses on a three-mode opto-mechanical interaction that can become unstable at high power, threatening the operational ability of the detector; multiple successful mitigation technique are presented and compared.
The results of this work, combined with the collaborative work of many others, allow the Advanced LIGO detectors to achieve a strain sensitivity better than 5 × 10−24/Hz1/2 during the third observation run.