file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L102
Operator Name: Gordon, Matt
Date: 1/28/2010 Time: 4:02 PM
Actuator Coil Resistance: 6.42 Ohms, PASS
Ambient Temperature: 70.6 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.534
Y Travel Limit (inches): 0.205
Z Travel Limit (inches): 0.508
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.174 |
20.031 |
9.214 |
PASS |
Position 1 |
0.250 |
0.080 |
0.217 |
2.356 |
20.013 |
8.493 |
PASS |
Position 2 |
0.250 |
-0.080 |
0.217 |
2.432 |
19.912 |
8.187 |
PASS |
Position 3 |
-0.250 |
-0.080 |
0.217 |
2.502 |
20.168 |
8.061 |
PASS |
Position 4 |
-0.250 |
0.080 |
0.217 |
2.485 |
19.919 |
8.014 |
PASS |
Position 5 |
-0.250 |
0.080 |
-0.217 |
2.400 |
20.091 |
8.372 |
PASS |
Position 6 |
-0.250 |
-0.080 |
-0.217 |
2.397 |
20.093 |
8.381 |
PASS |
Position 7 |
0.250 |
-0.080 |
-0.217 |
2.408 |
20.079 |
8.339 |
PASS |
Position 8 |
0.250 |
0.080 |
-0.217 |
2.393 |
20.106 |
8.402 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.182 |
-20.139 |
9.230 |
PASS |
Position 1 |
0.250 |
0.080 |
0.217 |
-2.384 |
-20.083 |
8.424 |
PASS |
Position 2 |
0.250 |
-0.080 |
0.217 |
-2.387 |
-19.979 |
8.371 |
PASS |
Position 3 |
-0.250 |
-0.080 |
0.217 |
-2.373 |
-19.977 |
8.419 |
PASS |
Position 4 |
-0.250 |
0.080 |
0.217 |
-2.369 |
-20.062 |
8.468 |
PASS |
Position 5 |
-0.250 |
0.080 |
-0.217 |
-2.390 |
-20.147 |
8.429 |
PASS |
Position 6 |
-0.250 |
-0.080 |
-0.217 |
-2.340 |
-19.954 |
8.529 |
PASS |
Position 7 |
0.250 |
-0.080 |
-0.217 |
-2.360 |
-19.825 |
8.399 |
PASS |
Position 8 |
0.250 |
0.080 |
-0.217 |
-2.391 |
-20.214 |
8.456 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11