file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L026
Operator Name: Smith, Lane
Date: 8/13/2009 Time: 3:18 PM
Actuator Coil Resistance: 6.45 Ohms, PASS
Ambient Temperature: 73.3 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.518
Y Travel Limit (inches): 0.207
Z Travel Limit (inches): 0.504
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.118 |
20.252 |
9.560 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.457 |
19.842 |
8.074 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.443 |
20.049 |
8.205 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.474 |
20.095 |
8.122 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.411 |
20.145 |
8.354 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.273 |
20.152 |
8.864 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.309 |
19.954 |
8.641 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.362 |
20.069 |
8.495 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.283 |
20.224 |
8.859 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.094 |
-19.924 |
9.514 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.347 |
-19.855 |
8.460 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.332 |
-20.110 |
8.622 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.363 |
-20.019 |
8.470 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.361 |
-20.080 |
8.504 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.353 |
-19.878 |
8.449 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.412 |
-20.182 |
8.367 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.384 |
-20.291 |
8.511 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.442 |
-20.217 |
8.278 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |