file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L029
Operator Name: Smith, Lane
Date: 8/11/2009 Time: 4:56 PM
Actuator Coil Resistance: 6.35 Ohms, PASS
Ambient Temperature: 72.5 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.527
Y Travel Limit (inches): 0.193
Z Travel Limit (inches): 0.483
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.104 |
20.187 |
9.592 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.517 |
19.950 |
7.925 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.366 |
20.510 |
8.667 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.475 |
20.246 |
8.181 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.436 |
20.211 |
8.295 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.287 |
20.091 |
8.784 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.301 |
19.958 |
8.674 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.265 |
19.967 |
8.816 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.298 |
20.035 |
8.718 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.112 |
-19.838 |
9.393 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.344 |
-20.016 |
8.541 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.337 |
-20.189 |
8.638 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.355 |
-20.217 |
8.586 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.355 |
-20.030 |
8.504 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.596 |
-20.041 |
7.720 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.441 |
-19.904 |
8.154 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.439 |
-20.153 |
8.262 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.521 |
-19.907 |
7.895 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart
scott.stewart@plansys.com
321-768-6500 x11
© 2009 QinetiQ North America, Technology Solutions Group |