LIGO Production Large Actuator Test Report |
Actuator Serial #: L007
Operator Name: Smith, Lane
Date: 8/11/2009 Time: 2:47 PM
Actuator Coil Resistance: 6.33 Ohms, PASS
Ambient Temperature: 76.9 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.511
Y Travel Limit (inches): 0.196
Z Travel Limit (inches): 0.483
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.107 |
19.877 |
9.436 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.404 |
20.112 |
8.366 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.414 |
20.323 |
8.418 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.418 |
20.354 |
8.417 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.479 |
20.350 |
8.209 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.174 |
19.875 |
9.144 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.411 |
20.531 |
8.516 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.332 |
20.579 |
8.826 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.278 |
19.910 |
8.742 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.121 |
-20.392 |
9.616 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.306 |
-20.124 |
8.725 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.302 |
-20.335 |
8.833 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.354 |
-20.383 |
8.657 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.312 |
-20.185 |
8.731 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.522 |
-19.983 |
7.923 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.609 |
-20.053 |
7.685 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.387 |
-20.391 |
8.543 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.418 |
-20.442 |
8.454 |
PASS |