file://localhost
LIGO Production Large Actuator Test Report |
Actuator Serial #: L032
Operator Name: Smith, Lane
Date: 8/12/2009 Time: 4:18 PM
Actuator Coil Resistance: 6.38 Ohms, PASS
Ambient Temperature: 71.8 F
Hi Pot Test Results: 1000 MOhms, PASS
X Travel Limit (inches): 0.520
Y Travel Limit (inches): 0.205
Z Travel Limit (inches): 0.503
|
X Position (in) |
Y Position (in) |
Z Position (in) |
Current (A) |
Force (lbs) |
Force Constant (lbs/A) |
PASS/FAIL |
Center |
0.000 |
0.000 |
0.000 |
2.129 |
20.173 |
9.475 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
2.328 |
20.071 |
8.620 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
2.325 |
19.921 |
8.569 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
2.320 |
19.866 |
8.562 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
2.439 |
20.044 |
8.217 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
2.229 |
20.124 |
9.027 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
2.339 |
19.869 |
8.494 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
2.283 |
19.892 |
8.714 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
2.341 |
20.174 |
8.619 |
PASS |
Center |
0.000 |
0.000 |
0.000 |
-2.098 |
-20.294 |
9.674 |
PASS |
Position 1 |
0.250 |
0.075 |
0.215 |
-2.313 |
-20.042 |
8.663 |
PASS |
Position 2 |
0.250 |
-0.075 |
0.215 |
-2.307 |
-20.126 |
8.722 |
PASS |
Position 3 |
-0.250 |
-0.075 |
0.215 |
-2.312 |
-20.222 |
8.745 |
PASS |
Position 4 |
-0.250 |
0.075 |
0.215 |
-2.309 |
-20.012 |
8.667 |
PASS |
Position 5 |
-0.250 |
0.075 |
-0.215 |
-2.355 |
-19.882 |
8.444 |
PASS |
Position 6 |
-0.250 |
-0.075 |
-0.215 |
-2.460 |
-20.009 |
8.134 |
PASS |
Position 7 |
0.250 |
-0.075 |
-0.215 |
-2.405 |
-19.860 |
8.256 |
PASS |
Position 8 |
0.250 |
0.075 |
-0.215 |
-2.355 |
-20.190 |
8.574 |
PASS |
QNA-TSG
1901 South Harbor City Blvd
Suite 700
Melbourne, FL 32901
Contact: Scott Stewart